Kabel Serat Optik Dalam Ruangan Penyangga Ketat Fanout Distribusi (GJFJV)
Parameter Teknis:
| Kabel Serat Optik Dalam Ruangan Fanout (GJFJV) | Diameter kabel | Berat | |
| 2 inti | 4,5 mm | 22,00kg/km | |
| 4 inti | 4,5 mm | 22,00kg/km | |
| 6 inti | 4,5 mm | 23,00kg/km | |
| 8 inti | 5,5 mm | 27,00kg/km | |
| 10 inti | 5,5 mm | 30,00kg/km | |
| 12 inti | 6,0 mm | 35,00kg/km | |
| Suhu penyimpanan (℃) | -20+60 | ||
| Radius Tekuk Minimum (mm) | Jangka panjang | 10D | |
| Radius Tekuk Minimum (mm) | Jangka pendek | 20D | |
| Kekuatan Tarik Minimum yang Diizinkan (N) | Jangka panjang | 200 | |
| Kekuatan Tarik Minimum yang Diizinkan (N) | Jangka pendek | 600 | |
| Beban Hancur (N/100mm) | Jangka panjang | 200 | |
| Beban Hancur (N/100mm) | jangka pendek | 1000 | |
Karakteristik serat:
| Gaya serat | Satuan | SMG652 | SMG652D | SMG657A | MM50/125 | MM62,5/125 | MMOM3-300 | ||
| kondisi | nm | Tahun 1310/1550 | Tahun 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | ||
| pelemahan | dB/km | ≤0,36/0,23 | ≤0,34/0,22 | ≤.035/0.21 | ≤3,0/1,0 | ≤3,0/1,0 | ≤3,0/1,0 | ||
| Penyebaran | 1550nm | Ps/(nm*km) | ---- | ≤18 | ≤18 | ---- | ---- | ---- | |
| 1625nm | Ps/(nm*km) | ---- | ≤22 | ≤22 | ---- | ---- | ---- | ||
| Lebar pita | 850nm | MHz.km | ---- | ---- | ≥400 | ≥160 | |||
| 1300nm | MHz.km | ---- | ---- | ≥800 | ≥500 | ||||
| Panjang gelombang dispersi nol | nm | ≥1302≤1322 | ≥1302≤1322 | ≥1302≤1322 | ---- | ---- | ≥ 1295,≤1320 | ||
| Kemiringan dispersi nol | nm | ≤0,092 | ≤0,091 | ≤0,090 | ---- | ---- | ---- | ||
| Serat Individu Maksimum PMD | ≤0,2 | ≤0,2 | ≤0,2 | ---- | ---- | ≤0,11 | |||
| Nilai Tautan Desain PMD | Ps(nm2*km) | ≤0,12 | ≤0,08 | ≤0,1 | ---- | ---- | ---- | ||
| Panjang gelombang batas serat λc | nm | ≥ 1180≤1330 | ≥tahun 1180≤1330 | ≥1180≤1330 | ---- | ---- | ---- | ||
| Pemutus kabelpanjang gelombang λcc | nm | ≤1260 | ≤1260 | ≤1260 | ---- | ---- | ---- | ||
| MFD | 1310nm | um | 9,2±0,4 | 9,2±0,4 | 9,0±0,4 | ---- | ---- | ---- | |
| 1550nm | um | 10,4±0,8 | 10,4±0,8 | 10,1±0,5 | ---- | ---- | ---- | ||
| NumerikBukaan (NA) | ---- | ---- | ---- | 0,200± 0,015 | 0,275±0,015 | 0,200±0,015 | |||
| Langkah (rata-rata dua arah)pengukuran) | dB | ≤0,05 | ≤0,05 | ≤0,05 | ≤0,10 | ≤0,10 | ≤0,10 | ||
| Ketidakteraturan pada seratpanjang dan titik | dB | ≤0,05 | ≤0,05 | ≤0,05 | ≤0,10 | ≤0,10 | ≤0,10 | ||
| Pemegatan | |||||||||
| Perbedaan backscatterkoefisien | dB/km | ≤0,05 | ≤0,03 | ≤0,03 | ≤0,08 | ≤0,10 | ≤0,08 | ||
| Keseragaman atenuasi | dB/km | ≤0,01 | ≤0,01 | ≤0,01 | |||||
| Diameter inti | um | 9 | 9 | 9 | 50±1,0 | 62,5±2,5 | 50±1,0 | ||
| Diameter pelapis | um | 125,0±0,1 | 125,0±0,1 | 125,0±0,1 | 125,0±0,1 | 125,0±0,1 | 125,0±0,1 | ||
| Pelapis non-sirkularitas | % | ≤1,0 | ≤1,0 | ≤1,0 | ≤1,0 | ≤1,0 | ≤1,0 | ||
| Diameter lapisan | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | ||
| Pelapis/chaffinchkesalahan konsentris | um | ≤12,0 | ≤12,0 | ≤12,0 | ≤12,0 | ≤12,0 | ≤12,0 | ||
| Pelapisan non-sirkularitas | % | ≤6,0 | ≤6,0 | ≤6,0 | ≤6,0 | ≤6,0 | ≤6,0 | ||
| Kesalahan konsentrisitas inti/selubung | um | ≤0,6 | ≤0,6 | ≤0,6 | ≤1,5 | ≤1,5 | ≤1,5 | ||
| Keriting(radius) | um | ≤4 | ≤4 | ≤4 | ---- | ---- | ---- | ||
Konstruksi Kabel:
Pemutus Kabel:
Kabel Multimode OM3 8 inti
Kabel mode tunggal 4 inti
Kabel Multimode 50/125 24 inti
Deskripsi:
•Kabel Serat Optik Indoor Penyangga Ketat Distribusi Fanout menggunakan 2~48 inti (atau lebih) dan menggunakan serat penyangga ketat 900μm atau 600μm sebagai sub-kabel optik. Biasanya, kabel ini menggunakan PVC atau LSZH, juga PE atau Nilon.
•Serat penyangga ketat dibungkus dengan lapisan benang aramid sebagai anggota kekuatan, kemudian dilengkapi dengan lapisan bahan PVC atau LSZH sebagai jaket luar.
•Warna jaket kabel serat optik dalam ruangan Fanout Distribusi Kedap Buffer:
Mode tunggal: Kuning,
Multimode OM1 / OM2: Oranye,
Multimode OM3 / OM4: Aqua,
Multimode OM4: Ungu,
Mutimode OM5: Jeruk nipis.
Warna lain bersifat opsional.
Aplikasi:
+ Digunakan dalam kuncir dan kabel patch.
+ Digunakan sebagai jalur interkoneksi peralatan, dan digunakan dalam koneksi optik di optikruang komunikasi, pusat data dan kerangka distribusi optik.
+ Digunakan pada pemasangan kabel dalam ruangan, terutama digunakan sebagai kabel distribusi.
Karakteristik:
•Karakteristik mekanis dan lingkungan yang baik.
•Karakteristik tahan api memenuhi persyaratan standar yang relevan.
•Karakteristik mekanis yang didongkrak memenuhi persyaratan standar yang relevan.
•Lembut, fleksibel, mudah dipasang dan disambung, serta memiliki kapasitas transmisi data yang besar.
•Memenuhi berbagai persyaratan pasar dan klien.
Aplikasi: digunakan untuk kabel dalam ruangan, kabel multi serat pigtail/ kabel patch
+ Digunakan dalam kuncir dan kabel patch.
+ Digunakan sebagai jalur interkoneksi peralatan, dan digunakan dalam koneksi optik di optik
ruang komunikasi dan rangka distribusi optik.
+ Digunakan pada pemasangan kabel dalam ruangan, terutama digunakan sebagai kabel distribusi.
Sedang mengemas: